CoreSite’s Atlanta AT1 data center facility is in the heart of downtown Atlanta at 55 Marietta Street NW, Atlanta, GA 30303. This strategic location serves as a vital hub for businesses to deploy their IT infrastructure. As one of the fastest-growing data center markets with the third-largest concentration of Fortune 500 companies in the U.S., Atlanta features tech-savvy organizations that look to CoreSite to help them future-proof their businesses.
>> CoreSite Atlanta (AT1) Facility Spec Sheet
The Atlanta data center campus operates as an integral part of the broader data center ecosystem within CoreSite, an American Tower Company. With a long-standing track record of operational experience, the Atlanta AT1 team offers the technical, security, remote hands and customer service expertise organizations rely on to meet their mission-critical needs. This 45,000-square-foot modern Atlanta data center space offers low-latency, redundant and secure colocation services to businesses of all sizes to dynamically scale their hybrid IT infrastructure.
FACILITY SIZE
45,000 sq.ft. of data center space
DEPLOYMENTS
Cabinets and cages
ROOFTOP
Space available
POWER AVAILABILITY
AC and DC
FIT OUT
Turn-key
PEERING EXCHANGES
Yes
CLOUD ACCESS
CoreSite Open Cloud Exchange® (OCX)
DIVERSITY
Diverse POEs, MDFs and IDFs
CROSS CONNECTS
Fiber, copper and coaxial
CARRIER AVAILABILITY
ACCESS
Key cards and controlled data center access
ENTRIES
CAMERAS
Perimeter and interior IP-DVR
PERIMETER
Controlled site access
SECURITY OFFICERS
24x7x365 security qualified personnel
UTILITIES
Diverse underground utility feeds from high-reliability electrical grid
UPS/PDU/RPP
N, 2N redundancy
GENERATORS
N redundancy
MECHANICAL
N+1 redundancy on pumps, HRUs, cooling towers and CRACs
REMOTE HANDS
BMS CONTROLS
State-of-the-art mission-critical controls and monitoring
UPTIME
99.999% uptime SLA
OPERATIONS
FLOOD PLAIN
FUEL STORAGE
48 hours, on-site
WATER STORAGE
FLOOR LOADING
Per floor 1,500 lbs. to 1,800 lbs. per cabinet dependent on cabinet aisle orientation
CLEAR HEIGHT
17’ above 24” raised floor 2nd floor. 13’ from slab to roof deck 5th, 8th and 16th floors.
COLUMN SPACING
23’ x 23’
LOADING DOCK
Sheltered interior. Exterior Roll up Door 78”h x 72”w
HARDENED EXTERIOR
Roof designed to withstand 125 MPH winds, Reinforced interior cross-bracing
ELEVATORS
Passenger: 48”w x 84”d x 80”h (2,000 lbs.) Freight: 48”w x 84”d x 84”h (3,500 lbs.)
WIFI
WiFi Available
WORK SPACE
TECH LOUNGE
PARKING
Secure parking available
CERTIFICATIONS
POWER UTILITY
ELECTRICAL
High-efficiency UPS systems
COOLING
Variable speed CRACs with humidification control
CHILLER
Chilled water with evaporative condensing units
LIFE SAFETY
Dual-interlock pre-action dry-pipe sprinkler system
LIGHTING
Lutron Eco-System lighting with occupancy sensors
MONITORING
Wired and wireless sensors readers for pinpoint accuracy of temperature and humidity within customer deployments in select areas
SOC 1 Type 2
SOC 2 Type 2
ISO 27001
NIST 800-53
PCI DSS
HIPAA